(Response format)
When processing is performed normally
When processing is not performed normally
(Parameters explanation)
Unit No.
Model No.
7
Target data
(Example)
The following sample command reregisters a model with unit number 3, model number 0 and target data
0.
<Command>
<Response>
USERACCOUNT or UAD
Adds user account to specified user group
Adds the user account to the specified affiliated group ID.
If the user account for the set image is already registered, that setting is overwritten.
516
Controlling/Outputting through Serial Communication (Non-procedure)
Specifies the processing unit number of a model to reregister: 0 to the number of unit data minus
one.
Specifies the model number to register a model: 0 to the uppermost unit model number in the unit.
Specifying a nonexistent model number causes an error.
Specifies the target data.
When the setting value is expressed in binary, if the 1st bit is 1, the model is re-registered.
When the setting value is expressed in binary, if the 2nd bit is 1, the reference position is updated.
When the setting value is expressed in binary, if the 3rd bit is 1, the detection position is updated.
Example)
- When only re-registering the model: 1 x 1 + 2 x 0 + 4 x 0 = 1 (setting value)
- When only updating the reference position: 1 x 0 + 2 x 1 + 4 x 0 = 2 (setting value)
- When updating or re-registering everything: 1 x 1 + 2 x 1 + 4 x 1 = 7 (setting value)