Omron FZ4 Series User Manual page 575

Vision sensor
Table of Contents

Advertisement

The error concerning
parallel interface was
detected.
Please turn off the
Turn OFF the power and check the connection state of the parallel interface.
power supply, and
confirm the connection
of parallel interface.
This is displayed when the application software detects an abnormality.
ProcItem error xxxx:
Please contact one of our branches or regional offices as there may be a software
xxxxerror
trouble.
No more scene can be added due to lack of memory.*
Review the inspection flow and reduce the memory consumption or switch to another
Failed to paste. Please
scene group.
check the save source
*) The display varies depending on the controller.
  The remaining capacity of the application is not sufficient for the FZ4-11
or the save destination.
  The remaining data memory capacity is not sufficient for the FZ4-L35
A camera outside the
guarantee is
A camera outside the guarantee is connected to the controller currently being used.
connected.
Check the following points.
Destination folder is not
found. Please check.
PLC link cannot be established. Check the following points.
PLC link error
Search, classification, flexible search, shape search+, shape search II
Please register higher-contrast images as models.
Fine matching
Failed to register model
For the fine matching, the 2 pixels at the edge of the image cannot be registered as the
model.
Available memory is
insufficient.
Available application memory is low.
It may cause
Memory may become insufficient during operation or an error may occur when the
insufficient memory
operation mode is switched.
depending on the
Review the inspection flow and reduce the memory consumption.
setting.
The free capacity of
RAMDisk is insufficient.
If nothing is done,
Clean up the content of RAMDisk to increase free space. If this error occurs even though
measurement cannot
enough free space is available, scene group data may be too large. Review the
be performed correctly.
inspection flow.
Increase free capacity
in RAMDisk.
FZ4 User's Manual
series.
Have you deleted the destination folder?
For cases where he save destination is the folder in the USBDisk, is the USBDisk
connected to the controller? Or, has the USBDisk been detected?
Are the FZ communication settings correct?
Are the PLC communication settings correct?
Is cable connected correctly?
Error Messages and Troubleshooting