Omron FZ4 Series User Manual page 388

Vision sensor
Table of Contents

Advertisement

Registered image setting
Registers a specified image data as a registered image. This operation results in the same operation as
when pressing the Register button on the Register Image Management tool. If the source to register is 0,
the last measured image, command argument 3 can be omitted.
Command (PLC to controller)
Command
area
top channel
+2
+3
+4
+5
+6
7
+7
+8
+9
Response (Controller to PLC)
Response
area
top channel
+2
+3
+4
+5
Loading registration images
Loads a specified registered image as a measured image. This operation results in the same operation
as when pressing the Load button on the Register Image Management tool.
386
Communicating through Serial Communication (PLC Link)
Command
15-12
code
8010
1000
0010
0000
0000
0000
0000
0000
0000
0000
Bit
15-12
11-8
1000
0000
0000
0000
0000
0000
0000
0000
Bit
11-8
7-4
0000
0001
0000
0001
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
7-4
3-0
0001
0000
0001
0000
0000
0000
0000
0000
Description
3-0
0000
Sets command codes.
0000
0000
Specifies the number of
the image to register. (0 to
0000
999)
0000
Specifies the type of data
to register from.
0: Last measured image
0000
1: Logging image
2: Image file
0000
Specifies the logging
image number or file
name.
Source to register:
Logging image number (0
to the number of logging
images in the controller -
0000
1) in the case of a
controller logging image.
Source to register: Image
file name (0 to 256
characters) in the case of
an image file.
Description
Command code
Store response target command codes.
Response code
Command execution result
OK: 0 (0000 0000)
NG: -1 (FFFF FFFF)
FZ4 User's Manual

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fz4 series

Table of Contents