Omron FZ4 Series User Manual page 278

Vision sensor
Table of Contents

Advertisement

Sets processing unit data
SetUnitData <unitNo>, <dataNo> | <dataIdent>, <data>
Parameters
<unitNo>
<dataNo>
<dataIdent>
<data>
4
Return Value
None.
Description
Performs the setting of the processing unit data of a processing item.
Example
Set to "Off" to "reflect to overall judgment" of the search processing unit processing unit number 2
SetUnitData 2, 103, 1
'or
SetUnitData 2, "overallJudge", 1
Notes
It is forbidden to modify parameters of image input category units from *MeasureProc.
Sets processing unit figure data
SetUnitFigure <unitNo>, <figureNo>, <figure()>
Parameters
<unitNo>
<figureNo>
<figure()>
Return Value
None.
Description
The integer type array variable of one dimension that stores the set graphic data is specified for the
argument < figure() > in shape to add only () without specifying the element number like XX&().
276
Using Custom Command
Processing unit No.
Data No.
Data identification name
Setting data
Processing unit number
The figure number to be set
The figure data to be set
FZ4 User's Manual