Omron FZ4 Series User Manual page 386

Vision sensor
Table of Contents

Advertisement

Scene data copy
Copies the data for the scene with the number specified with command argument 1 to the scene with the
number specified with command argument 2. If there is already data at the copy destination, the copied
data is written over that data.
Command (PLC to controller)
Command
area
top channel
+2
+3
+4
+5
+6
7
+7
Response (Controller to PLC)
Response
area
top channel
+2
+3
+4
+5
Scene data deletion
Deletes the data for the scene whose number is specified with command argument 1.
Command (PLC to controller)
Command
area
top channel
+2
+3
+4
+5
384
Communicating through Serial Communication (PLC Link)
Command
15-12
code
7010
0111
0010
0000
0000
0000
0000
0000
Bit
15-12
11-8
0111
0000
0000
0000
0000
0000
0000
0000
Command
15-12
code
7020
0111
0010
0000
0000
0000
Bit
11-8
7-4
0000
0001
0000
0001
0000
0000
0000
0000
0000
0000
0000
0000
7-4
3-0
0001
0000
0001
0000
0000
0000
0000
0000
Bit
11-8
7-4
0000
0010
0000
0001
0000
0000
0000
0000
Description
3-0
0000
Sets command codes.
0000
0000
Specifies the number of
0000
the scene to copy from.
0000
Specifies the number of
0000
the scene to copy to.
Description
Command code
Store response target command codes.
Response code
Command execution result
OK: 0 (0000 0000)
NG: -1 (FFFF FFFF)
Description
3-0
0000
Sets command codes.
0000
0000
Specifies the number of
0000
the scene to delete.
FZ4 User's Manual