Omron FZ4 Series User Manual page 414

Vision sensor
Table of Contents

Advertisement

Response (Controller to PLC)
Response
area
top channel
+2
+3
+4
+5
+6
+7
+8
+9
:
:
7
Getting image logging folder name
Gets the set image logging folder name.
Command (PLC to controller)
Command area
top channel
+2
+3
Response (Controller to PLC)
Response
area
top channel
+2
+3
+4
+5
+6
+7
Getting data logging folder name
Gets the set data logging folder name.
412
Communicating through Serial Communication (PLC Link)
Bit
15-12
11-8
0100
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
Command
15-12
code
4010
0100
0040
0000
Bit
15-12
11-8
0011
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
7-4
3-0
0000
0000
0100
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
Bit
11-8
7-4
0000
0001
0000
0100
7-4
3-0
0000
0000
0111
0000
0000
0000
0000
0000
0000
0000
0000
0000
Description
Command code
Stores response target command codes.
Response code
Command execution result
OK: 0 (0000 0000)
NG: -1 (FFFF FFFF)
Setting values related to image logging
Description
3-0
0000
Sets command
0000
codes.
Description
Command code
Store response target command codes.
Response code
Command execution result
OK: 0 (0000 0000)
NG: -1 (FFFF FFFF)
Response data
Folder name (absolute path)