Example 2) If there is a process after a [Parallel judgement output]
7
Output signal
Signal
RUN
BUSY
OR
DO
548
Controlling/Outputting through Parallel Communication
Turns on when the controller is available for measurement and the RUN window is displayed. It is
OFF in the ADJUST window, so switch to the RUN window during operation.
Indicates that controller is currently measuring or switching the scene. Do not input next command
while the BUSY signal is on. Otherwise, on-going processing or commands that are input will not be
performed correctly.
Outputs overall judgement. This is determined when the measurement is completed (BUSY signal
ON → OFF).
Selection of whether ON occurs during an OK judgement result or NG judgement result can be
performed in the communication specifications settings window.
Reference:
Setting Communication Specifications (Parallel Interface) (p.540)
Outputs the results for expressions set in the processing item [Parallel Judgement Output]/[Parallel
Data Output].
Selection of whether ON occurs during an OK judgement result or NG judgement result can be
performed in the communication specifications settings window.
Reference:
Setting Communication Specifications (Parallel Interface) (p.540)