ParallelIO
Configuration
Logging
Measure
Table: Data identification name 1
CameraControl (Camera delay setting)
cameraDelay0
cameraDelay1
cameraDelay2
4
cameraDelay3
UdpNormal (Communication - Ethernet setting)
portNo
enableDhcp
ipAddress
subnetMask
defaultGateway
destIpAddress
SerialNormal (Communication - Serial setting)
rsMode
baudRate
byteSize
parity
stopBits
softFlow
delimiter
timeout
multiDrop
mdUnitNo
broadcast
ParallelIO (Communication - Parallel setting)
polarity
handshake
cycleTime
298
Using Custom Command
Communication - Parallel setting
Language setting/Startup setting
Logging setting
Measurement control setting
STEP-camera 0 delay
STEP-camera 1 delay
STEP-camera 2 delay
STEP-camera 3 delay
Port number
Get an IP address automatically
0: OFF
1: ON
IP Address
Subnet mask
Default gateway
IP address to which the data is output
Communication type
0: RS-232C
1: RS-422
Baud rate (2400/4800/9600/19200/38400/576000/115200)
Data length (7, 8)
Parity
0: OFF
1: Odd
2: Even
Stop bit (1, 2)
Flow control
0: OFF
1: Xon/Xoff
Delimiter
0: CR
1: LF
2: CR+L
Timeout
Multidrop
0: OFF
1: ON
Model number
Broadcast under the multidrop connection
0: OFF
1: ON
Output polarity
Output control
Output cycle