<Command>
<Response>
DIOFFSET or DIO
Getting the terminal offset data
Acquires the DI terminal offset data.
The DI terminal offset is the value added to the command parameter for DI0-DI4 when a parallel
command is executed.
Once the terminal offset setting command has been executed, the acquisition command is enabled.
7
<Command format>
or
(Response format)
When processing is performed normally
When processing is not performed normally
(Parameters explanation)
Terminal offset data
This is the set value for the terminal offset (0-9999).
(Example)
When the terminal offset data is "10"
<Command>
<Response>
FZ4 User's Manual