Omron FZ4 Series User Manual page 574

Vision sensor
Table of Contents

Advertisement

Failed to switch scene
group or save scene
group on switch.
Failed to clear scene
group.
Failed to load scene
group.
Data is corrupted, or
memory is insufficient.
Scene group data
starts with initialized
status.
The camera connected
is not the same as the
one used for the last
save.
Please check.
Cannot read selected
file. Confirm selected
file once again.
8
The communication
time-out is occurred.
Failed to transfer data.
The free capacity of
RAMDisk may
insufficient
Increase the free
capacity of RAMDisk
and then perform this
operation again.
Error in input range.
Please input using the
correct range.
File name contains
invalid character.
Failed to save file.
Please check.
Fan/voltage error.
572
Error Messages and Troubleshooting
The cause of the failure to switch or to save when switching may be that the USBDisk
was removed from the controller. Set a USBDisk to the controller and try again.
Confirm that a USBDisk is set to the controller and try again.
The following causes are suspected:
The power may have been cut off during the last data save.
Because the operation mode was switched, the required memory size may have
increased and memory became insufficient.
Check if the camera is connected correctly.
This message is displayed when the system and the scene group 0 data edited using the
simulation software are loaded and the unit is restarted.
Save the setting to the controller and then restart.
Check the following points.
Have you removed the USBDisk from the controller after selecting files on the
USBDisk?
Have you deleted the selected file? (Such as the case when you selected a file on
the RAMDisk and the file was deleted via FTP.)
In addition, the selected file may be corrupt.
Switch off controller, verify the following contents and then restart.
Is cable connected correctly?
Does it comply with communication specifications of external devices?
Are external devices functioning normally?
If error is not resolved after confirmation, the controller may be damaged. Please discuss
this with one of our branches or regional offices.
Reference: Setting Communication Specifications (RS-232C/422-PLC Link) (p.368)
Reference: Setting Communication Specifications (RS-232C/422 - Non-procedure) (p.439)
Clean up the content of RAMDisk to increase free space. If this error occurs even though
enough free space is available, scene group data may be too large. Review the
inspection flow.
Please verify range for setting and set up again.
Please confirm that characters such as \ / , : ; * ? " < > |& . SPC (space) are not included
in the file name.
Check the following points.
Is the memory of the save destination sufficient?
For cases where the save destination is the folder in the USBDisk, is the USBDisk
connected to the controller? Or, the controller may not have detected the USBDisk.
Switch off controller, and verify if fan is affected. If error message is still shown after
restart, the controller may be damaged. Please contact one of our branches or regional
offices.
FZ4 User's Manual

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fz4 series

Table of Contents