About Connecting with External Devices

With the FZ4, serial interfaces and parallel interfaces can be used to communicate with external devices.
With serial interfaces, RS-232C/RS-422 and Ethernet can be selected as communication ports.
Non-procedure and PLC link can be used with either communication port.
Data transfer through EtherNet/IP (tag data link communication) or FTP is also possible with Ethernet.
Protocols usable with serial interface
The protocols that can be used with a serial interface are listed below.
Non-procedure
PLC link
7
With a parallel interface, control such as measurement control, scene group switching, scene switching,
clearing errors, clearing measurement values, clearing parallel terminals is possible.
Important
PLC link function refers to a function that communicates using 3 link areas indicated below: the command area,
response area and data output area.
It is different from the serial PLC link protocol used to inter-connect PLCs serially.
Connectable Models
Ethernet
Series name
SYSMAC_CJ2
SYSMAC_CJ1
SYSMAC_CS1
SYSMAC_CP1
SYSMAC_One
EtherNet/IP (tag data link communication)
Series name
SYSMAC NJ
SYSMAC_CJ2
360
About Connecting with External Devices
Controls the FZ4 through commands from a PC or specialized device.
Also possible to control from the PLC.
The FZ4 is controlled and measurement results are acquired only through data memory operations
in the PLC.
The FZ4 reads commands in the data memory (DM) and channel I/O (CIO) in the PLC, executes
measurement, and writes execution results to the data memory.
This is appropriate when the PLC is used as an external device.
The PLC supported by the FZ4 PLC link protocol is the SYSMAC CS/CJ/CP/One series PLC from
OMRON (models supporting FINS command) and PLC MELSEC Q series (protocol: MC protocol)
from Mitsubishi Electric Corporation.
CPU
CPU built-in port
CJ2H
Yes
CJ1H, CJ1G -
CJ1M
*Built-in type only
CS1H,CS1D,CS1G -
CP1L
-
CP1H
-
NSJ
*Built-in type only
CPU
NJ501,NJ301
CJ2M,CJ2H
Interface
CJ1W-EIP21 (PLC link only),CJ1W-ETN21
CJ1W-EIP21 (PLC link only),CJ1W-ETN21
CJ1W-EIP21 (PLC link only),CJ1W-ETN21
CS1W-EIP21 (PLC link only),CS1W-ETN21
CP1W-CIF41
CP1W-CIF41
NSJW-ETN21
Interface
CPU built-in port
Yes
*Built-in type only
Ethernet unit
EtherNet/IP unit
CJ1W-EIP21
CJ1W-EIP21
FZ4 User's Manual