BUSY
Input signal Scene switching
Signal
DI0 to 4
DI5
DI6
DI7
7
Reference
The amount of time during which the BUSY signal is turned ON when a scene is switched can be changed.
[Measurement setting] in the [Measure] menu Setting conditions related to operation during measurement
Input signal Scene group switching
Signal
DI0 to 4
DI5
DI6
DI7
554
Controlling/Outputting through Parallel Communication
Indicates that the controller is currently switching the scene or scene group. Do not input next
command while the BUSY signal is on. Otherwise, on-going processing or commands that are input
will not be performed correctly.
Set scene No. (0 to 31).
When a DI terminal offset is set, the setting value is added.
ON
OFF
This is the execution trigger.
After DI0 to 6 is set, turn DI7 on after an interval over 1 ms.
BUSY signal is on during implementation of commands. If the DI7 signal OFF timing cannot be set
faster than the BUSY signal OFF timing on the control side, set the scene switching additional time
to lengthen the BUSY signal OFF timing.
Set scene group No. (0 to 31).
When a DI terminal offset is set, the setting value is added.
ON
ON
This is the execution trigger.
After DI0 to 6 is set, turn DI7 on after an interval over 1 ms.
BUSY signal is on during implementation of commands. After checking that the BUSY signal has
turned on, turn DI7 off, and then turn DI0 to 6 off. If the DI7 signal OFF timing cannot be set faster
than the BUSY signal OFF timing on the control side, set the scene switching additional time to
lengthen the BUSY signal OFF timing.