3.
Set the trigger detailed settings as required.
6
Trigger signal
When phase A
When phase Z
354
Setting the System Operation Environment
Set value
Setting item
[Factory default]
[Phase A]
●
Phase Z
●
[ENABLE
●
Enable
start]
timing
STEP start
●
[Every trigger
●
pulse]
Pulse reset
Every
●
timing
rotation
(Pulse Z)
Pulse A
[0] to 65536
Support
[Checked]
●
backlashing
Unchecked
●
Trigger in
Checked
●
backlashing
[Unchecked]
●
Description
Sets the phase to be used as the trigger signal.
Sets the timing for starting the pulse count.
ENABLE start: Counts the pulses input during the
measurement trigger receipt period.
STEP start: Does not count pulses even during the
measurement trigger receipt period until the STEP
signal is input.
Sets the timing for resetting.
When it is every rotation, multiple settings for
phase A are possible.
Sets how many pulses it takes for the trigger to be
produced.
Sets whether the rotation direction is detected.
Sets whether a trigger is produced during reverse
rotation.
FZ4 User's Manual