Using Method Of Ng Analyser - Omron FZ4 Series User Manual

Vision sensor
Table of Contents

Advertisement

4.
Measurement data
Display the desired unit in the list of units and select the unit based on details of unit and
details of data.

Using Method of NG Analyser

Important
Classify sample images beforehand into the OK folder containing images you want to judge OK or NG folder
containing images you want to judge NG. (The applicable file types are "*.IFZ", "*.BYR" and "*.BMP".)
Do not input external commands or STEP signals while the NG analyser is running (excluding during non-stop
adjustment).
1.
On the Main screen, tap [Tool] menu - [NG analyser].
The analyser screen is displayed.
2.
Specify the image file.
Specify the upper rank folder containing the OK and NG folders.
Although logging images of the controller can be set as the target, all logging images of the
controller, if selected, are treated as "Not yet judged."
You can also set a reference image to perform adjustment.
FZ4 User's Manual
Using NG Analyser
115
4