Omron FZ4 Series User Manual page 511

Vision sensor
Table of Contents

Advertisement

The current image logging save condition is "1: Only NG".
Changes settings related to image logging
Changes setting related to current image logging.
<Command format>
<Response format>
When processing is performed normally
When processing is not performed normally
<Parameters explanation>
Setting data
Image Logging
Folder name of image logging save
destination
Prefix for image logging file name
Data Logging
Name of destination folder for
saving data logging
Important
Specifying the name of a folder to save to
The method for specifying the name of the folder to save to depends on the model.
For FZ4-11
series
For RAMDisk   C:\Data\RAMDisk
For USB memory   E:\,F:\
For FZ4-L35
/6
For RAMDisk   \RAMDisk
For USB memory   \USBDisk、\USBDisk2
For the FZ4-11
series, do not save to a non-volatile area on the C drive (such as C:\ProgramFiles\FZ). This
would reduce the storage area for scene data etc. and make correct operation impossible.
(Example 1)
When creating settings so that image logging is only performed during NG errors
FZ4 User's Manual
Identifier 1
imageLogging
imageLoggingDirectory
imageLoggingHeader
dataLogging
dataLoggingDirectory
/7
series
Controlling/Outputting through Serial Communication (Non-procedure)
Set value
0: None
1: Only NG
2: All
Save destination folder name (one-byte alphanumeric
character)
Prefix for image logging file name (one-byte
alphanumeric characters)
0: None
1: Only NG
2: All
Save destination folder name (one-byte alphanumeric
character)
7