Important
Set the image mode to "Freeze".
●
When loading images continuously at high speed, the number of images that can be loaded is limited. Once the
●
maximum number of images have been loaded, the READY signal will not turn on until the current measurement
processing is complete. Accordingly, the next STEP cannot be input.
Reference:
If STEP is input while READY is off, the ERROR terminal turns on.
●
If triggers are input continuously and too quickly for the communication output to catch up, some steps may not
●
be output or measurement delays may occur. Input triggers at appropriate timings that do not cause
communication delays.
The multiple image input function cannot be used in the following cases:
●
Multiple camera input processing units are present in the flow.
●
An Camera Image Input HDR is present in the flow.
●
1 camera input processing unit is used in multiple processes using the branching function.
●
Measurement triggers are input other than in the parallel mode (such as when non-procedure commands or
●
PLC-link measurement commands are sent).
7
560
Controlling/Outputting through Parallel Communication
About Max. Number of Loading Images during Multiple Image Input (p.614)
FZ4 User's Manual