Address setting
7
I/O setting
[Note 1]: This is not displayed if the communication module is set to "Non-procedure (TCP)" or
"non-procedure (TCP Client)".
438
Controlling/Outputting through Serial Communication (Non-procedure)
Setting item
Obtain an IP address automatically
[Use the following IP address]
IP address
Subnet mask
Default gateway
DNS server
Input mode
Input form
[Note 1]
Output IP address
[Note 2]
TCP Server
Input/Output port No.
Setting value
[Factory default]
Set the IP address of the
controller.
When "Obtain an IP address
automatically" is selected, the IP
address of the controller will be
automatically obtained.
When "Use the following IP
address" is selected, set the IP
address, subnet mask, and the
default gateway address.
a.b.c.d
a: 1 to 223
b: 0 to 255
Input the controller IP address.
c: 0 to 255
d: 0 to 255
[10.5.5.100]
0.0.0.0 to
255.255.255.255
Input the subnet mask address.
[255.255.255.0]
a.b.c.d
a: 1 to 223
b: 0 to 255
Input the default gateway address.
c: 0 to 255
d: 0 to 255
[10.5.5.110]
a.b.c.d
a: 1 to 223
b: 0 to 255
Input the DNS server address.
c: 0 to 255
d: 0 to 255
[10.5.5.1]
[Normal]
This item cannot be changed.
[ASCII]
This item cannot be changed.
a.b.c.d
a: 1 to 223
b: 0 to 255
Input the output destination IP
c: 0 to 255
address.
d: 0 to 255
[0.0.0.0]
a.b.c.d
a: 1 to 223
b: 0 to 255
Input the TCP server IP address.
c: 0 to 255
d: 0 to 255
[10.5.5.101]
0 to 65535
Set the port No. to use for data I/O
[9600] [9876]
with the controller. Set the same
[Note
No. as on the host side.
3]
Description
FZ4 User's Manual