8. Before installing new corona wires, moisten a clean, dust-free cloth with water
and remove dust and corrosion from the inner and outer surfaces of the
precharge and preclean corona assemblies (1).
1
9. Do the following to replace the precharge and preclean corona wires, one at a
time:
a. Locate the new corona cartridge.
b. Attach the corona wire ring (1) to the wire terminal (2) at the rear wire
holder (3) on the corona assembly.