Ricoh InfoPrint 4100 TS2 Operating Manual page 175

Table of Contents

Advertisement

v All interventions are cleared. If interventions exist, you may have to manually
re-thread the forms and then select Check Reset until all interventions are
cleared and remain cleared.
About this task
A jam occurring between Printer 1 and Printer 2 normally causes the forms to tear
and separate. Printer 1 continues to print and dump forms out on the floor
between Printer 1 and Printer 2. Printer 2 feeds forms and prints until an 078A END
OF FORMS message appears on Printer 2. At that time, both printers stop feeding
forms.
The following procedure gives you a method of splicing the separated forms back
together between Printer 1 and Printer 2 so that re-threading of Printer 2 and a
postprocessing device (if installed) is not required.
Procedure:
Procedure
1. Do one of the following depending on whether the forms can be spliced:
a. If the forms were damaged during the separation and there is sufficient
slack in the forms, splice the forms together at the Printer 2 splicing table.
See "Splicing tractored forms" on page 150.
b. If forms were damaged by the separation and must be removed or there is
not enough slack to splice the forms together, select the appropriate paper
advance (feed page) key on the Align Forms panel or on the printer
operator panel, to advance the forms through Printer 1 enough to splice the
forms at the Splicing Table of Printer 2.
2. Select Forms → Align Forms to display the Align Forms panel.
Chapter 5. Working with forms
161