a. Measure the width of the mark (2) that the lower mark sensor will be
reading. In step (e) this measurement will be used to center the sensor light
on the mark.
b. Locate the mark on the underside of the form in the form loop just before
the upper mark sensor assembly (7) and make a pin hole about 1/4 of an
inch in front and to the left of the mark.
c. Advance the forms until the pinhole (2) is just past the upper mark sensor
assembly (7).
d. Align the opening of the mark alignment guide (10) to the pinhole (2) by
rotating the mark sensor positioning knob (6).
e. Open the upper mark sensor assembly (7) by raising the upper mark sensor
assembly lever (8).
1
7
f. Using the pinhole as a guide position the opening of the scale alignment
guide (11) next to the mark (2) using the Forms Feed Reverse button (3).
While in sensor adjustment mode these buttons will move the forms very
slowly
g. Close the upper mark sensor assembly (7).
1
3
4
5
9
6
8
Chapter 5. Working with forms
11
12
2
207