c. Tighten the thumbscrew (2).
Note: The thumbscrew (4) adjusts the position of the sensor on the bottom
side of the sensor mounting plate. It must be turned fully counterclockwise
to position the sensor to read the side verify or registration marks at the
outside edge of the paper (this is the default position). If you change the
location of the marks (Forms → Special Marks), you must adjust the
position of the sensor.
9. See "Adjusting the Universal Forms Control (UFC) sensor" on page 199 or
"Adjusting the rear paper-edge guide and Dual Toner Mark/Side Verify
Sensor" on page 146 for more information.
What to do next
If you are changing to a different size form on Printer 1, you must change the
forms on Printer 1. See "Changing forms settings on Printer 1." If you are using
the Auto Load sequence to load the forms, you must set the form length at the
stacker control panel. See "Setting the forms length for Auto Load" on page 134.
Changing forms settings on Printer 1
Before you begin
Do this procedure to select and load the correct Snapshot when you are changing
to a different size form on Printer 1.
Note: Do this step when loading forms in Dual Simplex mode or loading Printer 1
in Duplex mode.
3
1
4
Chapter 5. Working with forms