Cosmetic Care & Maintenance

Diesel Generator-Checking/Changing Fuses

A circuit breaker in line interrups the generator output
in the event of a fault in the wiring between the generator
and the load. The line circuit breaker is shown in the
typical parts description on the previous page. If the
breaker "blows", reduce the load and switch the breaker
to the ON position.
The engine junction box on the 9EOZD model contains
three 10 amp in-line fuses. Always identify the cause of
a blown fuse before restarting the generator. See the
troubleshooting section for more information or call your
closest authorized dealer.
A replaceable 10 amp fuse protects the controller circuitry.
If the controller display is dark, check the battery and
battery connections and then check the controller fuse.
Replace the fuse if it is blown.
A replaceable 10 amp fuse protects the engine relays. If
the generator set does not crank, check the battery and
battery connections and then check the relay fuse. Replace
the fuse if it is blown.
A replaceable 10 amp fuse protects the alternator.
Note: Some fuses are ceramic, others are of the glass
type. Replace with identical type and amperage.
159