Notice that each battery switch features an on and off
position. Upon leaving the vessel it is recommended that
each battery switch be turned to the "off "position. This
will deactivate both engines and the house related circuits.
The automatic bilge pumps will still operate with these 3
battery switches turned off.
There are three 105 amp resetable circuit breakers
mounted on the battery switch panel for each individual
battery switch. At times when the battery charger or the
alternators are not charging the batteries it protects the
wiring from the battery isolator to the battery terminal.
If a circuit breaker "pops" determine the root cause
before resetting the breaker.
CAUTION
!
AVOID POSSIBLE FIRE
AND/OR EQUIPMENT DAMAGE.
DO NOT TURN THE BATTERY SWITCHES
TO THE "OFF" POSITION WITH
THE ENGINES RUNNING.

DC CIRCUIT PROTECTION

A source of engine circuit protection is located on the
engine itself. Notice that the engine breaker is resetable.It
is located on the engine. Refer to chapter 4 or consult the
engine owner's manual for detailed information.
The engine breaker powers the key switch as well as the
engine dash gauges. It does not power the dash switches
such as bilge pump, blower, etc. If the engine circuit
breaker "pops" determine the cause of the malfunction
before resetting the breaker.

DC DISTRIBUTION CENTER

circuit breakers. If a breaker should "pop" determine
the root cause of the problem before resetting the breaker.
NOTICE
AS A SAFETY FEATURE
THE FORWARD AND AFT BILGE PUMP
CIRCUITRY IS CONTINUOUSLY PROVIDING
PROTECTION EVEN WITH THE BATTERY
SWITCHES AND DC DISTRIBUTION
CENTER OFF.
3
Systems
The DC distribution
center panel located at
the
engine
forward
b u l k h e a d p r o v i d e s
protection for the dash
main,
cabin
main,
windlass and electronics
circuitry. Each of these
appliances use resetable