DANGER
!
AVOID INJURY OR DEATH
DUE TO CO POISONING!
NEVER OPERATE THE GENERATOR
WITHOUT A FUNCTIONING
CO DETECTOR.
♦ Fuel Level- Check your fuel tank levels.
♦ Oil Level- Keep the oil level topped off with the cor-
rect type and even with the dipstick top mark.
♦ ♦ ♦ ♦ ♦ On diesel generators the water separator filter should
be checked for moisture and debris which will be located
at the bottom of the sediment bowl. Drain as needed
and retighten all hardware. Dispose properly of all flu-
ids and rags.
♦ Operating Area- Check for anything that could block
the flow of air. Keep the air intake area clean. Never leave
tools, rags, or debris on or near the generator set.
♦ Seawater Pump Priming- To prime the pump:
1. Close the seacock.
2. Remove the hose from the water filter outlet.
3. Fill the hose and seawater pump with clean water.
4. Reconnect the hose to the water filter outlet.
5. Open the seacock.
6. Confirm the seawater pump operation on startup as
indicated by water discharge from the exhaust outlet.
Under normal conditions the consumer should not need
to prime the seawater pump unless the boat has been out
of the water for extended periods.