Brush
Measure the brush length.
If more than limit, replace the brush.
Standard: 5 mm (0.20 in)
Rectifier Assembly
Check for continuity across "1" and "2" in the
range of multimeter.
Change polarity, and make sure that there is continuity in
one direction, and not in the reverse direction. In case of
continuity in both directions, replace the rectifier
assembly.
STARTING AND CHARGING SYSTEM (X22SE 2.2L)
Reassembly
To reassemble, follow the disassembly steps in the
reverse order, noting the following points:
1. Install pulley on the rotor.
Clamp pulley to the vise, and tighten nut to the
specified torque.
Torque: 40 N·m (30 lb ft)
066RW009
100W
066RW011
6D3–13
066RS010