15. Select F2: Low Fan Relay.
16. Push "On" and "Off" of soft key.
17. Control Low Fan Relay and check a data list.
18. If the data list changes, the Low Fan Relay is normal.
19. Run the Fan Motor.
20. Select F3: High Fan Relay.
21. Push "On" and "Off" of soft key.
22. Control High Fan Relay and check a data list.
If the data list changes, the High Fan Relay is normal.
23. Run the Fan Motor.
RODEO X22SE 2.2L ENGINE DRIVEABILITY AND EMISSION
060RX048
060RX049
EVAP Test
This test is conducted check EVAP system for its working.
Tech 2 must be used for this test.
Test Procedure:
1. Connect Tech 2 to the vehicle DLC.
2. Run the Engine at idle.
3. Select F3: Miscellaneous Test in the Application
Menu.
4. Select F2:EVAP Test in the Miscellaneous Test.
6E1–41
060RW228
060RX050