6D3–6
STARTING AND CHARGING SYSTEM (X22SE 2.2L)
Continuity of Series Coil
Check for continuity between terminals S and M.
Replace, if there is no continuity (i.e., coil is
disconnected).
Continuity of Contacts
With the plunger faced downward, push down the
magnetic switch. In this state, check for continuity
between terminals B and M. Replace, if there is no
continuity (i.e., contacts are faulty).
Pinion
Check if the pinion rotates smoothly in drive direction by
hand, or if it is locked when it is rotated in reverse. If not,
replace the pinion.
Characteristic Test
For easily confirming the characteristics, conduct the
noload test as follows:
065RW017
Rating as short as 30 seconds requires rapid testing.
Fix the starter on the test bench, and wire as shown in
illustration. When the switch is closed, the current flows
and the starter runs under no load. At this time, measure
current, voltage and speed to check if they satisfy the
standard.
065RW018
Legend
(1) Volt Meter
(2) Revolution Indicator
(3) Battery
(4) Ammeter
(5) Switch
065RS025
065RW020