Dot1X Timeout Quiet-Period - HP Bc1500 - BladeSystem - Blade PC Reference Manual

Blade switch
Hide thumbs Also See for Bc1500 - BladeSystem - Blade PC:
Table of Contents

Advertisement

dot1x timeout quiet-period

The dot1x timeout quiet-period Interface Configuration mode command sets the number of
seconds that the device remains in the quiet state following a failed authentication exchange (for
example, the client provided an invalid password). To return to the default configuration, use the
no form of this command.
Syntax
dot1x timeout quiet-period seconds
no dot1x timeout quiet-period
Parameters
seconds — Specifies the time in seconds that the device remains in the quiet state following a
failed authentication exchange with the client. (Range: 0-65535 seconds)
Default Setting
The default quiet period is 60 seconds.
Command Mode
Interface Configuration (Ethernet) mode
Command Usage
During the quiet period, the device does not accept or initiate authentication requests.
The default value of this command should only be changed to adjust for unusual circumstances,
such as unreliable links or specific behavioral problems with certain clients and authentication
servers.
To provide a faster response time to the user, a smaller number than the default value should be
entered.
Example
In the following example, the number of seconds that the device remains in the quiet state
following a failed authentication exchange, is set to 3600.
Console(config)# interface ethernet 1/e16
Console(config-if)# dot1x timeout quiet-period 3600
HP PC Blade Switch CLI Reference Guide
www.hp.com
802.1x Commands
2-7

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bladesystem pc

Table of Contents