Action:
013: The MLID could not register Protocol ID number for protocol stack name for
frame type type.
Source:
Explanation:
Action:
014: This version of the LSL is not supported.
Source:
Explanation:
Action:
015: The frame type is already active for frame type.
Source:
Explanation:
Action:
760 System Messages
Correct the protocol entry in the NET.CFG file. The proper syntax for the
protocol keyword is as follows:
PROTOCOL TRXNE hex_protocol_ID frame_type
TRXNET-DOS.LAN
The Link Support Layer (LSL) is configured with resources for a set number
of Protocol Identifiers. (The default is 4.) This number has been exceeded.
Edit the NET.CFG file, and add the MAX STACKS keyword to reflect the
number of network boards to be loaded, as in the following example:
LINK SUPPORT
MAX STACKS 6
Unload the driver; then reload it as in the following example:
C:\NWCLIENT\TRXNET /u <Enter>
C:\NWCLIENT\LSL /u <Enter>
C:\NWCLIENT\LSL <Enter>
C:\NWCLIENT\TRXNET <Enter>
TRXNET-DOS.LAN
The driver you are using supports only Link Support Layer (LSL) versions
later than 1.0.
Unload the LSL and replace it with a newer version.
TRXNET-DOS.LAN
The frame type is already loaded, and it cannot be loaded repeatedly.
Edit the NET.CFG file to load the frame type only once for a given network
board.
Need help?
Do you have a question about the NETWARE 6-DOCUMENTATION and is the answer not in the manual?