Action:
223: The board must be placed in a 16-bit slot.
Source:
Explanation:
Action:
224: This board is configured as an NE1000.
Source:
Explanation:
Action:
233: The adapter detected a duplicate station during the insertion process.
Source:
Explanation:
Action:
235: The adapter cable was disconnected during the insertion process.
Source:
Explanation:
Action:
236: The ring was beaconing during the insertion process.
Source:
Explanation:
Action:
768 System Messages
Replace the network board with one that works. For information about a
specific error code, search the
www.novell.com/documentation/lg/nwec/docui/index.htm).
NE2000-NW.LAN
The network board was placed in an 8-bit slot.
Move the network board to a 16-bit slot.
NE2000-NW.LAN
The board is responding with an NE1000 ROM signature.
Make sure the I/O port settings on the network board match the I/O port
settings in the AUTOEXEC.NCF file. If the settings match, replace the
network board.
CNTR2000.LAN
Another network board is using the same node address.
Use a different node address.
CNTR2000.LAN
The network board could not access the network because the cable was
disconnected.
Securely fasten the cable links, reboot the workstation, and reload the driver.
CNTR2000.LAN
The network board could not access the network because it is set at an
incorrect data rate.
Set the network board to the correct data rate.