4 Wiring and Connection

4.2.2 INDEXER Module I/O Signal (CN11) Names and Functions

(2) CN1 Output Signals
Signal
Name
ALM+
ALM-
/WARN+
(/SO1+)
/WARN-
(/SO1-)
/BK+
(/SO2+)
/BK-
(/SO2-)
/S-RDY+
(/SO3+)
/S-RDY-
(/SO3-)
FG
Note: The allocation of /SO1, /SO2, and /SO3 can be changed to /ALO1, /ALO2, and /ALO3 by using PnB51. For details,
refer to 5.3.3 Servo Alarm Output Signal (ALM) and Alarm Code Output Signals (/ALO1, /ALO2, and /ALO3).
4.2.2

INDEXER Module I/O Signal (CN11) Names and Functions

(1) CN11 Input Signals
4-4
Pin No.
Large-
Σ-V
Capacity
Σ-V
3
31
Servo Alarm Output
4
32
1
25
Warning Signal Output
2
26
23
27
Brake Signal Output
24
28
25
29
Servo Ready Output
26
30
Connector Shell
Frame Ground
Ensure that the following condition does not last longer than 5 minutes. Otherwise the
product life may be shortened.
• The ambient temperature is high, and,
• There is a high ratio of CN11 input signal contacts that are ON (closed)
*2
ratio
).
The allowable ranges for ambient temperature and contact ON ratio are shown below.
100
90
80
70
60
50
40
30
20
10
0
0
∗1. The state that a contact is ON (closed) indicates, regardless of the logic of the
input signal, that the contact is closed and that current is flowing in the input
circuit.
∗2. For example, a contact ON ratio of 100% indicates that 11 out of the 11 con-
tacts are ON.
Name
Servo Alarm:
Turns OFF when an error is detected.
Error/Warning:
ON for 2 seconds when an error has occurred.
ON continuously while a warning is being detected.
Brake interlock (controls the brake):
ON when the brake is released.
Servo Ready:
ON when the control and main circuit power supplies are
ON and a Servo Alarm has not occurred.
By connecting the shielded wire of the I/O signal cable to
the connector shell, it will be connected to the frame
ground (earth).
Ambient temperature and input signal contact ON ratio
If values in this range continue for
5 minutes or longer, the product
life may be shortened.