3.2 I/O Signal Connections

3.2.1 I/O Signal Connector (CN1) Names and Functions

3.2
I/O Signal Connections
3.2.1
I/O Signal Connector (CN1) Names and Functions
The following table gives the pin numbers, names, and functions the I/O signal pins for the
default settings.
Input Signals
Default settings are given in parentheses.
Signal
*
/SI1
(P-OT)
*
/SI2
(N-OT)
*
/SI3
(/DEC)
*
/SI4
(/EXT1)
*
/SI5
(/EXT2)
*
/SI6
(/EXT3)
*
/SI0
+24VIN
BAT+
BAT-
A-FB
*
You can change the allocations. Refer to the following manual for details.
Σ
S800001 28)
Note: If forward drive prohibition or reverse drive prohibition is used, the SERVOPACK is stopped by software con-
trols. If the application does not satisfy the safety requirements, add external safety circuits as required.
3-4
Pin No.
General-purpose Sequence
7
Input 1 (Forward Drive Prohibit
Input)
General-purpose Sequence
8
Input 2 (Reverse Drive Prohibit
Input)
General-purpose Sequence
9
Input 3 (Origin Return Decel-
eration Switch Input)
General-purpose Sequence
10
Input 4 (External Latch Input
1)
General-purpose Sequence
11
Input 5 (External Latch Input
2)
General-purpose Sequence
12
Input 6 (External Latch Input
3)
General-purpose Sequence
13
Input 0
Sequence Input Signal Power
6
Supply Input
Battery for Absolute Encoder
14
(+)
Battery for Absolute Encoder
15
(-)
5
Gap Sensor Signal Input
Σ
-7-Series
-7S SERVOPACK with MECHATROLINK-III Communications References Product Manual (Manual No.: SIEP
Name
You can allocate the input signal to use with a
parameter.
(Stops Servomotor drive (to prevent overtravel)
when the moving part of the machine exceeds the
range of movement.)
You can allocate the input signal to use with a
parameter.
(Connects the deceleration limit switch for origin
return.)
You can allocate the input signals to use with
parameters.
(Connect the external signals that latch the current
feedback pulse counter.)
You can allocate the input signal to use with a
parameter.
(Used for general-purpose input. You can monitor
this signal in the I/O monitor field of
MECHATROLINK.)
Inputs the sequence input signal power supply.
Allowable voltage range: 24 VDC ±20% The 24-
VDC power supply is not provided by Yaskawa.
These are the pins to connect the absolute
encoder backup battery.
Do not connect these pins if you use the Encoder
Cable with a Battery Case.
Inputs the analog signal that is output from the
gap sensor. Refer to the following section for
details on the connection.
3.3 Connecting the Gap Sensor on page 3-7