Parameter
No.
/START-STOP; /HOME
Setting
Starts program table operation when /START-STOP signal
is ON (close).
0
Stops program table operation when /START-STOP signal
PnB04
is OFF (open).
Starts program table operation when /START-STOP signal
is OFF (open).
1
Stops program table operation when /START-STOP signal
is ON (close).
2, 3
Does not start program table operation.
/PGMRES; /JOGP
Setting
Resets program table operation by switching /PGMRES
0
signal from OFF (open) to ON (close). Program table oper-
PnB05
ation is canceled.
Resets program table operation by switching /PGMRES
1
signal from ON (close) to OFF (open). Program table oper-
ation is canceled.
2, 3
Does not reset program table operation.
/SEL0; /JOGN
Setting
0
PnB06
1
2
3
/SEL1; /JOG0
Setting
0
PnB07
1
2
3
Name
Setting Range
Mode 0
Mode 0
Mode 0
When input signal is ON (close), program table selection
signal /SEL0 becomes active.
When input signal is OFF (open), program table selection
signal /SEL0 becomes active.
Program table selection signal /SEL0 is always active.
Program table selection signal /SEL0 is always inactive.
Mode 0
When input signal is ON (close), program table selection
signal /SEL1 becomes active.
When input signal is OFF (open), program table selection
signal /SEL1 becomes active.
Program table selection signal /SEL1 is always active.
Program table selection signal /SEL1 is always inactive.

10.1 Parameter List for INDEXER Module

Setting
Unit
0 to 3
Meaning
Starts homing when input signal is ON (close).
Starts homing when input signal is OFF (open).
Does not start homing.
0 to 3
Meaning
Executes JOG operation in the forward direction when
input signal is ON (close).
Executes JOG operation in the forward direction when
input signal is OFF (open).
Does not execute JOG operation.
0 to 3
Meaning
Executes JOG operation in the reverse direction when input
signal is ON (close).
Executes JOG operation in the reverse direction when input
signal is OFF (open).
Does not execute JOG operation.
Does not execute JOG operation.
0 to 3
Meaning
When input signal is ON (close), JOG speed table selection
signal /JOG0 becomes active.
When input signal is OFF (open), JOG speed table selec-
tion signal /JOG0 becomes active.
JOG speed table selection signal /JOG0 is always active.
JOG speed table selection signal /JOG0 is always inactive.
(cont'd)
Factory
When
Reference
Setting
Enabled
0
After restart
6.1.2, 6.4.2
Mode 1
0
After restart
6.1.2, 6.4.2
Mode 1
0
After restart
6.1.2, 6.4.2
Mode 1
0
After restart
6.1.2, 6.4.2
Mode 1
10