YASKAWA S-V Series User Manual page 173

Ac servo drives indexer module
Hide thumbs Also See for S-V Series:
Table of Contents

Advertisement

Alarm
Alarm Name
Display
Encoder Output Pulse
A.041
Setting Error
Parameter Combination
A.042
Error
Semi-closed/Fully-
A.044
closed Loop Control
Parameter Setting Error
Parameter Setting Error
A.04A
2
A.050
Combination Error
Unsupported Device
A.051
Alarm
Linear Scale Pitch
A.080
Setting Error
Canceled Servo ON
A.0b0
Command Alarm
Overcurrent or Heat
A.100
Sink Overheated
A.300
Regeneration Error
A.320
Regenerative Overload
Main Circuit Power
A.330
Supply Wiring Error
A.400
Overvoltage
A.410
Undervoltage
A.42A
Converter Error
Main-Circuit
A.450
Capacitor Overvoltage
Meaning
The encoder output pulse setting
Rotational
(pulse unit) (Pn212) is outside the
motors
allowable setting range or does not
satisfy the setting conditions.
The encoder output resolution set-
Linear
ting (Pn281) is outside the allow-
motors
able setting range or does not
satisfy the setting conditions.
Combination of some parameters exceeds the
setting range.
The settings of the feedback option module and
Pn00B.3, Pn002.3 do not match.
There is an error in settings of parameters
reserved by the system.
The SERVOPACK and the servomotor capaci-
ties do not match each other.
The unsupported device unit was connected.
The setting of the linear scale pitch (Pn282) has
not been changed from the default setting.
The host controller reference was sent to turn
the Servo ON after the Servo ON function was
used with the utility function.
An overcurrent flowed through the IGBT.
Heat sink of the SERVOPACK was overheated.
Regenerative circuit or regenerative resistor is
faulty.
Regenerative energy exceeds regenerative
resistor capacity.
• Setting of AC input/DC input is incorrect.
• Power supply wiring is incorrect.
Main circuit DC voltage is excessively high.
Main circuit DC voltage is excessively low.
One of the following was detected by the con-
verter.
• An operation error occurred when using the
limit relay for inrush current
• PN voltage error
• The converter's heat sink overheated
• An operation error occurred when using the
converter and fan
The capacitor of the main circuit has deterio-
rated or is faulty.
9.1 Troubleshooting
Servomotor
Alarm Code Output
Alarm
Stop
Reset
/ALO1 /ALO2 /ALO3
Method
Gr.1
N/A
Gr.1
N/A
Gr.1
N/A
OFF
(open)
Gr.1
N/A
Avail-
Gr.1
able
Gr.1
N/A
Gr.1
N/A
Avail-
Gr.1
able
ON
Gr.1
N/A
(close)
Avail-
Gr.1
able
Avail-
ON
Gr.2
able
(close)
Avail-
Gr.1
able
Avail-
Gr.1
able
Avail-
Gr.2
able
OFF
(open)
Avail-
Gr.1
able
Gr.1
N/A
(cont'd)
OFF
OFF
(open)
(open)
OFF
OFF
(open)
(open)
ON
OFF
(close)
(open)
OFF
ON
(open)
(close)
9
9-3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sgdv-oca03a

Table of Contents