YASKAWA S-V Series User Manual page 226

Ac servo drives indexer module
Hide thumbs Also See for S-V Series:
Table of Contents

Advertisement

10 Appendix
Parameter
No.
Input Signal Selection 6
4th
digit digit digit digit
n.    
*7
Pn515
Pn517
Reserved (Do not change.)
Excessive Error Detection Level Between Servo-
*1
Pn51B
motor and Load Position
Pn51E
Excessive Position Error Warning Level
Pn520
Excessive Position Error Alarm Level
Pn522
Reserved (Do not change.)
Pn524
Reserved (Do not change.)
Pn526
Excessive Position Error Alarm Level at Servo ON
Excessive Position Error Warning Level at Servo
Pn528
ON
*1
Speed Limit Level at Servo ON
Pn529
*1
Multiplier per One Fully-closed Rotation
Pn52A
Pn52B
Overload Warning Level
Derating of Base Current at Detecting Overload of
Pn52C
Motor
Pn52F
Reserved (Do not change.)
∗1. Parameter exclusive for rotational servomotors
∗7. This parameter is for the Large-Capacity Σ-V Series.
10-26
Name
3rd
2nd 1st
Reserved (Do not change.)
Reserved (Do not change.)
Dynamic Brake Answer signal 1 Input Signal Mapping (/DBANS1)
0
Detects dynamic brake (DB) contactor errors when the input signal of CN1-40 is ON (closed) while the DB
is applied.
1
Detects DB contactor errors when the input signal of CN1-41 is ON (closed) while the DB is applied.
2
Detects DB contactor errors when the input signal of CN1-42 is ON (closed) while the DB is applied.
3
Detects DB contactor errors when the input signal of CN1-43 is ON (closed) while the DB is applied.
4
Detects DB contactor errors when the input signal of CN1-44 is ON (closed) while the DB is applied.
5
Detects DB contactor errors when the input signal of CN1-45 is ON (closed) while the DB is applied.
6
Detects DB contactor errors when the input signal of CN1-46 is ON (closed) while the DB is applied.
7 and 8
Disables DB contactor error detection of DB answer signal 1.
9
Detects DB contactor errors when the input signal of CN1-40 is OFF (open) while the DB is applied.
A
Detects DB contactor errors when the input signal of CN1-41 is OFF (open) while the DB is applied.
B
Detects DB contactor errors when the input signal of CN1-42 is OFF (open) while the DB is applied.
C
Detects DB contactor errors when the input signal of CN1-43 is OFF (open) while the DB is applied.
D
Detects DB contactor errors when the input signal of CN1-44 is OFF (open) while the DB is applied.
E
Detects DB contactor errors when the input signal of CN1-45 is OFF (open) while the DB is applied.
F
Detects DB contactor errors when the input signal of CN1-46 is OFF (open) while the DB is applied.
Reserved (Do not change.)
Setting
Factory
Units
Range
Setting
0000 to FFFF
8888
0000
0 to
1
1073741824
reference
1000
30
unit
(2
)
10 to 100
1%
1 to
1
1073741823
reference
5242880
30
unit
(2
-1)
1073741824
1 to
1
1073741823
reference
5242880
30
unit
(2
-1)
10 to 100
1%
-1
0 to 10000
10000
1 min
0 to 100
1%
1 to 100
1%
10 to 100
1%
0FFF
When
Classification
Enabled
After restart
Setup
Immediately
Setup
100
Immediately
Setup
Immediately
Setup
1
Immediately
Setup
100
Immediately
Setup
Immediately
Setup
20
Immediately
Setup
20
Immediately
Setup
100
After restart
Setup
(cont'd)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sgdv-oca03a

Table of Contents