YASKAWA S-V Series User Manual page 153

Ac servo drives indexer module
Hide thumbs Also See for S-V Series:
Table of Contents

Advertisement

8 Operation of Digital Operator
8.2.2 Program Table Edit/Save (FnB03)
 LOOP: Number of Executions
Note: For details on the number of executions, refer to 6.1.4 (1) Program Table Functions.
 NEXT: PGMSTEP to be Executed Next
Note: For details on the PGMSTEP to be executed next, refer to 6.1.4 (1) Program Table Functions.
(4) Saving Program Tables
The operating procedure for saving program tables is shown below.
Step
1
2
3
4
5
6
If the
the display returns to the program table editing screen. In this case, make the setting again by referring to (1) Prepara-
tion.
8-10
Move cursor
Move cursor
Display after Operation
key is pressed in an operation prohibited state, "Error." is displayed for approximately 2 seconds and then
Change number of executions
Change next PGMSTEP to be executed
If the value becomes less than 0,
"END" is displayed.
Keys
Display the program table editing screen.
Press the
operation screen.
Move the cursor with the
"STORE".
Note: Selecting "CANCEL" and pressing the
will return the display to the program table edit-
ing screen.
Press the
key to start saving the program table to
*
flash memory.
Do not turn off the control power supply until saving
has been completed normally.
When saving to flash memory has been completed nor-
mally, the display returns to the program table editing
screen.
Press the
key to return to the Utility Function
Mode main menu.
Operation
key to view the program table save
keys to select
key

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sgdv-oca03a

Table of Contents