7.7.6 Zone Table Setup Commands
The following table shows the Zone Table Setup Commands.
Serial Command
Zone Table Save
Saves the zone table in flash memory.
ZONESTORE
Once ZONESTORE is executed, the zone table will be retained
after the control power supply is turned OFF. Because the zone
table is stored in flash memory, this command must not be exe-
cuted frequently.
Zone Table Initialization
ZONEINIT
Resets all values in the zone table to their factory settings.
Zone Table ZONEP Read
ZONEPTzz
Reads the ZONEP value (positive side zone boundary position.)
zz: Zone number (ZONE ID)
Zone Table ZONEP Write
Sets the ZONEP value (positive side zone boundary position).
ZONEPTzz = nnnnnnnn
zz: Zone number (ZONE ID)
Settings: −99999999 ≤ nnnnnnnn ≤ +99999999
Zone Table ZONEN Read
ZONENTzz
Reads the ZONEN value (negative side zone boundary posi-
tion.)
zz: Zone number (ZONE ID)
Zone Table ZONEN Write
Sets the ZONEN value (negative side zone boundary position).
ZONENTzz = nnnnnnnn
zz: Zone number (ZONE ID)
Settings: −99999999 ≤ nnnnnnnn ≤ +99999999
Zone Table Setup Commands
Function/Description
7.7 Serial Commands
Positive Response
OK
OK
ZONEPT123 = +12345678 [CR] [LF]
OK
ZONENT123 = +12345678 [CR] [LF]
OK