10 Appendix
Parameter
No.
Σ-V Series
Application Function Select Switch D
4th
digit
n.
Large-Capacity Σ-V Series
Application Function Select Switch D
Pn00D
4th
digit digit digit digit
n.
Pn00F
Reserved (Do not change.)
Axis Address Selection
Pn010
(For UART/USB communications)
10-16
Name
3rd
2nd
1st
digit
digit
digit
Stand-alone Mode (Test Operation) Selection
Enables connection with the command option module.
0
1
Disables connection with the command option module.
Reserved (Do not change.)
Reserved (Do not change.)
Reserved (Do not change.)
3rd
2nd 1st
Stand-alone Mode (Test Operation) Selection
0
Enables connection with the command option module.
1
Disables connection with the command option module.
Dynamic Brake Signal Selection
0
Enables the control of an NO contactor
(The dynamic brake is activated when current is supplied to the contactor coil.)
1
Enables the control of an NC contactor
(The dynamic brake is activated when current is not supplied to the contactor coil.)
Reserved (Do not change.)
Overtravel Warning Detection Selection
0
Does not detect overtravel warning.
1
Detects overtravel warning.
Setting
Factory
Units
Range
Setting
0000 and 0001
–
0000
−
0000 to 1011
0000
–
–
0000
0000 to 007F
–
0001
(cont'd)
When
Classification
Enabled
Immediately
Setup
Immediately
Setup
–
–
After restart
Setup