YASKAWA S-V Series User Manual page 209

Ac servo drives indexer module
Hide thumbs Also See for S-V Series:
Table of Contents

Advertisement

Parameter
No.
Input Signal Monitor IN1 Polarity
Selection
Bit
0
1
2
3
PnB53
4
5
6
7
Name
Setting Range
0000 to 00FF
Setting
0
The polarity for bit 0 (/SVON) of input signal monitor IN1 is not reversed.
Photocoupler is OFF when bit 0 is 0.
Photocoupler is ON when bit 0 is 1.
1
The polarity for bit 0 (/SVON) of input signal monitor IN1 is reversed.
Photocoupler is ON when bit 0 is 0.
Photocoupler is OFF when bit 0 is 1.
0
The polarity for bit 1 (/ALM-RST) of input signal monitor IN1 is not reversed.
Photocoupler is OFF when bit 1 is 0.
Photocoupler is ON when bit 1 is 1.
1
The polarity for bit 1 (/ALM-RST) of input signal monitor IN1 is reversed.
Photocoupler is ON when bit 1 is 0.
Photocoupler is OFF when bit 1 is 1
0
The polarity for bit 2 (P-OT) of input signal monitor IN1 is not reversed.
Photocoupler is OFF when bit 2 is 0.
Photocoupler is ON when bit 2 is 1.
1
The polarity for bit 2 (P-OT) of input signal monitor IN1 is reversed.
Photocoupler is ON when bit 2 is 0.
Photocoupler is OFF when bit 2 is 1
0
The polarity for bit 3 (N-OT) of input signal monitor IN1 is not reversed.
Photocoupler is OFF when bit 3 is 0.
Photocoupler is ON when bit 3 is 1.
1
The polarity for bit 3 (N-OT) of input signal monitor IN1 is reversed.
Photocoupler is ON when bit 3 is 0.
Photocoupler is OFF when bit 3 is 1
0
The polarity for bit 4 (/DEC) of input signal monitor IN1 is not reversed.
Photocoupler is OFF when bit 4 is 0.
Photocoupler is ON when bit 4 is 1.
1
The polarity for bit 4 (/DEC) of input signal monitor IN1 is reversed.
Photocoupler is ON when bit 4 is 0.
Photocoupler is OFF when bit 4 is 1
0
The polarity for bit 5 (Not used) of input signal monitor IN1 is not reversed.
Bit5 is invalid.
1
The polarity for bit 5 (Not used) of input signal monitor IN1 is reversed.
Bit5 is invalid.
0
The polarity for bit 6 (/RGRT) of input signal monitor IN1 is not reversed.
Photocoupler is OFF when bit 6 is 0.
Photocoupler is ON when bit 6 is 1.
1
The polarity for bit 6 (/RGRT) of input signal monitor IN1 is reversed.
Photocoupler is ON when bit 6 is 0.
Photocoupler is OFF when bit 6 is 1
0
The polarity for bit 7 (Not used) of input signal monitor IN1 is not reversed.
Bit7 is always 0.
1
The polarity for bit 7 (Not used) of input signal monitor IN1 is reversed.
Bit7 is always 0.
10.1 Parameter List for INDEXER Module
Setting
Factory
Unit
Setting
0050
Meaning
(cont'd)
When
Reference
Enabled
After restart
7.7.8
Factory Setting
0
0
0
0
1
0
1
0
10-9
10