Datafilling table LCMINV
Table line concentrating module inventory (LCMINV) lists data assignments
for each bay that associate with a local or remote LCM unit. The SITE is
the only field different for the RSC-S configuration.
The datafill for table LCMINV appears in the following example. This table
only contains fields that apply to basic call processing. Field FRTYPE
contains new information. Refer to the data schema section of the
Translations Guide for a description of the other fields.
Datafilling table LCMINV
Subfield or
Field
refinement
LCMNM
SITE
FRNO
UNITNO
FRTYPE
EQPEC
Note 1: The LCM link info is listed starting with link 0. The C-side peripheral links are in
parentheses.
Note 2: When you enter field link information (LNKINFO), make sure message links are not
assigned to the same interface card. Make sure message links are not assigned to the same
interface card when you enter field link map (LNKMAP). When the interface card supports two or
more links, separate the message links by the number of links on the interface cards. This
occurrence applies to all interface link types; DS-1, DS30, DS30A, or PCM-30. Table control issues
a warning if an attempt is made to assign message links on the same interface card. The
assignment of message links to the same interface card can cause an E1 outage (failure of all
message links). The E1 outage can occur if the card fails.
DMS-100 Family XPM International Translations Reference Manual XPM12 and up
Datafilling BAS on RSC-S International
Basic call processing
Entry
Explanation and action
refer to
Line concentrating module name. Enter the
subfields
LCM name. Subfields: SITE, FRNO, and
UNITNO.
alphanumeric
Site. Enter the remote location site name.
SITE is a subfield of field LCMNM.
0 to 511
Frame number Enter the LCM frame number.
0 to1
Unit number. Enter the LCM unit number.
refer to list
Frame type. Enter the frame type where the
peripheral module equipment mounts. Enter
CRSC for the RCO2 shelf. Enter CEXT for the
RCO2 extension shelf. Enter the location of the
RCO2 in fields FRNO, SHPOS, FLOOR, ROW,
and FRPOS.
BX30AB
Equipment PEC. Enter PEC BX30AB for the
LCME.
—continued—
3-73