Nortel DMS-100 Series Reference Manual page 89

Extended peripheral module
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

Datafilling table RCCINV
Subfield or
Field
refinement
OPTCARD
MX76LOC
PROTOCOL
Note: When you enter data in field C-side link table (CSLNKTAB), make sure message links are
not assigned to the same interface card. When the interface card supports two or more links,
separate the message links by the number of links on the interface cards. This action applies to all
interface link types: DS-1, DS30, DS30A, or PCM-30. If an attempt to assign message links is
made on the same interface card, table control issues a warning. The assignment of message links
to the same interface card can cause an E1 outage (failure of all message links). The E1 outage
can occur if the card fails.
DMS-100 Family XPM International Translations Reference Manual XPM12 and up
(continued)
Entry
see list
REM
HDLC or
DMSX
NT7X05AA
—continued—
Datafilling BAS on RSC-S International
Basic call processing
Explanation and action
Optional card. This is a vector of a maximum of
10 entries. For the RCO2, slot 4 must be used
for the ISDN signaling pre-processor (ISP) card.
Slots 6 and 7 can be used for the universal tone
receiver (UTR) cards. The class modem
resources (CMR) card can only be plugged to
slot 5. The NTMX76 card, can be used for
extended distance capability, in slots 8 and 20.
Examples are CMR5, ISP, UTR6, UTR7, PRL,
and MSGMX76.
Note: If the NTMX76 card is used at the
remote, it must also be present at the host.
Note: Changes to fields with multiple entries
must be made in the PROMPT mode only.
NTMX76 card location. Defines the location of
the NTMX76 card, remote or host. Only REM is
acceptable for the remote peripheral.
Protocol. Defines whether HDLC mode is
present and is active. If active, the remote shelf
operates in HDLC after initialization. The
remote PM must be busied before this value is
changed. Entry is mandatory if the NTMX76
card is entered.
If NT7X05AA is entered, the system prompts for
the slot_number. Slot number for the
NT7X05AA in the RCO2 is 5 and 21 or 7 and
23.