4-36 Datafilling BAS on RSC-S UK / Europe
Basic call processing
Datafilling table CLLI
Subfield or
Field
refinement
TRKGRPSIZ
ADMININF
TRAFCLS
ADMININF
OFFCLS
(continued)
TRKGRTYP
Note 1: The maximum number of CLLI codes is 8192.
Note 2: The SIZE field in table DATASIZE allocates memory for entry with field DATSKEY equal to
CLLI.
Example of entries for table CLLI
The following is an example of entries for table CLLI .
MAP display example for table CLLI
Table: CLLI
CLLI
________________________________________________________
SYNCH
OFFHKSUP
ALMSC
RMMVER90
LTU
297-8331-815 Standard 10.01 August 1999
(continued)
(continued)
Entry
0 to 2047
refer to
subfields
alphanumeric
or – for no
entry
alphanumeric
or – for no
entry
alphanumeric
or blank
ADNUM
23
45
58
79
177
Description
Trunk group size is 4-character field. This field
is equal to the maximum expected number of
trunk members in the trunk group.
Administrative information is a 32-character
field. The operating company uses this field to
record administrative information. The
switching unit does not use the information.
The recommended subfields are TRAFCLS,
OFFCLS, and TRKGRTYP.
Trunk group traffic class is an optional field.
This field is for administrative purposes.
Office class is an optional field. This field is for
administrative purposes. When field
TRKGRTYP is blank OFFCLS can be left blank.
Trunk group type is an optional field. This field
is for administrative purposes.
—end—
TRKGRPSIZ
ADMININF
10
SYNCH/NONSYNCH
10
SUPERVISION_SIGNAL_OFFHOOK
240
ALARM_SC
10
ALARM_SD
10
LINE_TEST_UNIT