Nortel DMS-100 Series Reference Manual page 482

Extended peripheral module
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

5-22 Datafilling Remote Switching Center Multi-Access
Remote Switching Center Multi-access (RSC-M)
Datafilling table SITE
Subfield or
Field
refinement
MODCOUNT
OPVRCLLI
POINT
Note 1: The system allocates memory for a maximum of 32 sites.
Note 2: Make changes to fields with multiple entries in the PROMPT mode.
Datafill example for table SITE
Sample datafill for table SITE appears in the following example.
MAP display example for table SITE
Datafilling table PMLOADS
Table PMLOADS stores the device location of every PM loadfile. This
process permits the XPM automatic loading feature to locate load files
without the interruption of operating company personnel.
Table PMLOADS lists the active and backup loadfiles. The active loadfile
is the default load used with the LOADPM command and most system
activities. The system uses the backup loadfile if a problem occurs when the
system loads or returns the active loadfile to service. The backup loadfile is
the unpatched loadfile shipped. The active and backup loadfiles are used
during the application and removal of patches.
297-8331-815 Standard 10.02 March 2004
(continued)
Entry
0
Ver90 or
alphanumeric
0–6
NAME
LTDSN
MODCOUNT
––––––––––––––––––––––––––––––––––––––––––––––––––––
RSCM
00
Description
Module count. Range is 0 to 1000.
Operator verification CLLI. Enter the CLLI
assigned to the operator verification trunk group
at the remote location.
Point. Enter the signal distributor point number
in the trunk module circuit number assigned to
the alarm. Where entry is for the host switching
unit, leave blank.
—end—
OPVRCLLI
6
MH5_RSCM
(continued)
ALMDATA
$

Advertisement

Table of Contents
loading