Nortel DMS-100 Series Reference Manual page 284

Extended peripheral module
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

4-34 Datafilling BAS on RSC-S UK / Europe
Basic call processing
Datafilling table OFCENG
The following table describes the data for RSC-S International for table
OFCENG. The table describes the fields that apply to Basic call processing.
For additional information about office parameters, refer to Office
Parameters Reference Manual.
Datafilling table OFCENG
Field
TALK_BATTERY_ALARM
Parameter TALK_BATTERY_ALARM
This parameter turns on the audits of the talk battery in
LCM/XLCM/LCME/RLCM/OPM/OPAC peripheral modules. When this
parameter changes, activation is immediate.
Example of entries for table OFCENG
The following is an example of entries for table OFCENG. In this example,
the table lists the new parameter to allow the talk battery alarm audit. For
additional information about office parameters, refer to Office Parameters
Reference Manual.
Example of OFCENG table MAP display
–––––––––––––––––––––––––––––––––––––––––––––––––––––––
Datafilling table CLLI
The CLLI codes identify the far end of each announcement, tone, trunk
group and test trunk. The CLLI codes also identify the far end of the
national milliwatt test lines and service circuits.
297-8331-815 Standard 10.01 August 1999
(continued)
Entry
Y or N
Default is Y
Table OFCENG
TALK_BATTERY_ALARM
Description
TALK_BATTERY_ALARM. This parameter
turns on the audits of the talk battery in
LCM/XLCM/LCME/RLCM/OPM peripheral
modules.
PARMNAME
PARMVAL
Y

Advertisement

Table of Contents
loading