Nortel DMS-100 Series Reference Manual page 161

Extended peripheral module
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

MAP example for table RCCINV datafilled for NTAX74AA CAP
Datafilling table RCCPSINV
Table remote cluster controller P-side link inventory (RCCPSINV) contains
RCO2 P-side link assignments. Table RCCPSINV can contain a maximum
of 54 multiples of P-side link information for the RCO2.
For an extension shelf, data entry limits apply for RCO2 P-side links. The
data entry limits apply to P-side links connected to the extension shelf. The
PCM-30 and D-channel handler (DCH) links that connect to the extension
shelf can contain data. These links can contain data if an extension shelf has
data entered in RCCINV. All links that connect to the extension shelf must
change from D30/DCH to NILTYPE or DS30A in RCCPSINV. All links
must change before the deletion of the extension shelf from table RCCINV.
Table RCCPSINV can contain a maximum of ten DCH cards.
The data entry for table RCCPSINV appears in the following procedure.
This procedure contains fields that apply to PCM-30 R1 Trunking. Refer to
the data schema section of the Translations Guide for a description of the
other fields.
DMS-100 Family XPM International Translations Reference Manual XPM12 and up
Table: RCCINV
RCCNAME
FRTYPE FRNO SHPOS FLOOR ROW FRPOS
––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
MELB RCO2 0
CRSC
EXECTAB
(POTS POTSEX)(KEYSET KSETEX)(ABTRK DTCEX)
(RMM_TERM RSMEX) (ESALINES ESAEX)
CSPM
CSLNKTAB
––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
PLGC 1
(0) (1) (2) (3) (4) (5) (6) (7)
ESA
INTRASW
OPTCARD
––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
N
Y
(UTR6)(MSG6X69)
TONESET
PROCPEC
––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
AUS100
AX74AA
AX74AA
Note: 2 PCM-30 C-side links (1 and 2) are required. The data control
table for P-side links is table RCCPSINV. Table RCCPSINV requires
data in link 1 to be datafilled before link 2. If only two links are
required, link 1 is ManB. Enter data for three links in this table.
Datafilling PCM-30 trunks on RSC-S International 3-137
PCM-30 R1 Trunking
0
18
0
C
E2LOAD
EXTINFO
AX74xxxx
CEXT 0 4 0 E 15 MX86AA L
(continued)
EQPEC
LOAD
0
MX85AA
WRI07xx
CMRLOAD
(CMR18 CMRAG03)
$
$
$

Advertisement

Table of Contents
loading

Table of Contents