Datafilling table RCCINV
Subfield or
Field
refinement
EXECTAB
EXEC
(continued)
ESA
Note 1: A loss of ISDN calls occurs during ESA warm switch of activity. The ESA warm switch of
activity for stable ISDN calls has support in XPM06.
Note 2: When you enter data for field C-side link table (CSLNKTAB), perform the following action.
Make sure message links are not assigned to the same physical interface card. When the interface
card supports two or more links, separate the message links by the number of links on the interface
cards. This requirement applies to all interface link types; DS-1, DS30, DS30A or PCM-30. Table
control issues a warning if an attempt to assign message links on the same interface card occurs.
The assignment of message links to the same interface card can cause an E1 outage if the card
fails. An E1 outage is a failure of all message links.
DMS-100 Family XPM International Translations Reference Manual XPM12 and up
Datafilling ESA lines and trunks on RSC-S UK / Europe 4-117
(continued)
Entry
ESAEX
Y or N
—continued—
ESA lines and trunks
Explanation and action
Executive programs. Enter the set of executive
programs the PM requires. The TRMTYPE
entry specifies this PM. Entry values include
the following:
POTSEX if TRMTYPE is POTS
KSETEX if TRMTYPE is KEYSET
RSMEX if TRMTYPE is RMM_TERM
DTCEX or FXODCM if TRMTYPE is
ABTRK. The entry value depends on the
type of trunking.
ESAEX if TRMTYPE is ESALINES
Emergency stand-alone. Entry values are Y
and N. The Y indicates that the RSC-S has the
ESA option. The N indicates that the RSC-S
does not have the ESA option.
(continued)