Nortel DMS-100 Series Reference Manual page 399

Extended peripheral module
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

Datafilling ISDN on RSC-S UK / Europe 4-149
ISDN operations
(continued)
Table CLLI stores the maximum number of trunk groups that can be
assigned to the trunk group. The table also stores a miscellaneous entry
for administrative information that the switching unit does not use.
The system adds some CLLI codes to table CLLI when the feature is
present in the switch. Add other codes to the CLLI table. After you
enter data in table CLLI, the following tables reflect the CLLI tables.
— the trunk group tables
— the scan and distribution point table
— the MTA tables
The CLLI tuple for operator verification must duplicate in field
OPVRCLLI in table SITE.
Note: Enter data in some tables by the kind of trunk group type
required. Each trunk group type requires a specified form. Valid trunk
group types are TI, TO, T2, IBNTI, IBNTO, IBNT2, PX and ES.
Table LTCINV contains inventory data, except the P-side link
assignment, for PM types. This table defines the PCM-30 line group
controller (PLGC) or line group controller overseas (LGCO) on the
C-side of the RCO2. Load information for this table is entered in field
LOAD and corresponds to the LOADNAME tuple from table
PMLOADS.
Table LTCPSINV contains the assignment of the P-side links for PMs.
If D30 is entered in AREASELCT, the CARRIDX field indexes table
CARRMTC for maintenance control information about the peripheral.
Note: The RSC-S can be configured with the PLGC or the LGCO. The
datafill entry must be:
PLGC
Field LTCNAME in table LTCINV corresponds to the LTCNAME field
in table LTCPSINV.
Load information is entered in field LOADNAME. Corresponding
entries are entered in field LOAD for tables LTCINV, LCMINV and
RMMINV.
DMS-100 Family XPM International Translations Reference Manual XPM12 and up