Nortel DMS-100 Series Reference Manual page 498

Extended peripheral module
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

5-38 Datafilling Remote Switching Center Multi-Access
Remote Switching Center Multi-access (RSC-M)
Datafilling table CARRMTC
Subfield or
Field
refinement
ATTR
CRCRST
(continued)
SIGNTYPE
Note 1: The DMS switch adds the first tuple for the RSC-M to table CARRMTC during IPL or first
restart after IPL. The CAS is SIGNTYPE of the default tuple and the switch cannot delete or change
this tuple.
Note 2: Add tuples other than the default tuple before the tuples can be referenced in the table
RCCPSINV.
Note 3: Out-of-service timers in the AMC must be greater than the equivalent timers in the DMS
switch.
Note 4: Return-to-service timers in the AMC must be smaller than the equivalent timers in the DMS
switch.
Datafill example for table CARRMTC
Sample datafill for table CARRMTC appears in the following example.
MAP display example for table CARRMTC
CSPMTYPE TMPLTNM RTSML
––––––––––––––––––––––––––––––––––––––––––––––––––––
RCO2 DEFAULT 255 255 D30 NTMX82AA A_LAW NATL 4 4 17 255
297-8331-815 Standard 10.02 March 2004
(continued)
Entry
numeric
(0 to 255)
5=500 msec
CAS
—end—
4 4 17 255 4 4 17 255 4 4 17 255 4 4 17 255
130 20 17 255 N 4 4 17 255
914 G714 CAS
(continued)
Description
RTS time for CRC4 alarm. Enter the RTS time
for the CRC4 alarm. This value appears in
units of 100 ms.
The default value for this field is 5.
Signaling type. Enter CAS for
channel-associated signaling
RTSOL
ATTR
N N 5 5 205