3-92 Datafilling BAS on RSC-S International
Basic call processing
Datafilling table ALMSC
The function each of the assigned scan points in the alarm scan groups
appears in table alarm scan (ALMSC). Refer to the data schema section of
the Translations Guide for a description of the other fields.
Datafilling table ALMSC
Subfield or
Field
refinement
FUNCTION
SCGROUP
POINT
NORMALST
REPORT
ALM
LOGIC
LOGIC
SDFUNCT
ALMGRP
297-8331-815 Standard 10.01 August 1999
(continued)
Entry
Explanation and action
alphanumeric
Function. Enter the alarm function.
0 to 255
Scan group. Enter the scan group where the
scan point belongs.
0 to 7
Scan point. Enter the scan point number in the
scan group.
0 or 1
Normal state. Enter the normal state of the
scan point. Entry values: 0, if the scan point is
normally off or open. The entry value is 1 if the
scan point is normally on or closed.
Y or N
Alarm report. Enter Y if an alarm report must
be logged. Otherwise, enter N.
refer to list
Alarm type. Enter the type of alarm to activate.
Entry values: CR (critical alarm), MJ (major
alarm), MN (minor alarm), and NA (no alarm).
refer to
Logic. Subfields: LOGIC, SDFUNCT, ALMGRP,
subfields
ALMXFR, and CONTMARK.
Y or N
Logic. Enter Y if the logic that associates with
the function is fixed; otherwise enter N.
alphanumeric
Signal distributor function. Enter the signal
distributor function or functions that associates
with an exact scan point.
Y or N
Alarm grouping. Enter Y if the alarms are
activated when the alarm grouping key is
activated. Enter N if the alarm function is
activated at all times if the alarm grouping key
does not affect function.
—continued—