Datafilling table RMMINV
Table remote maintenance module inventory (RMMINV) identifies an
RLCM, RSC-S, or OPM site with the frame type, frame number, floor or
row attached to each RMM. The RMMINV also identifies an RLCM,
RSC-S, or OPM site with the frame position, PEC, PM load and executive
program loaded, and C-side PM attached to each RMM. Memory is
dynamically allocated and the maximum size of this table is 255 entries.
The CSPMINFO field of an RMM can be an RCO2, PLGC/LGCO or RCC.
The C-side links of RMM must be defined to links 22 and 23 of the RCO2.
The datafill for table RMMINV appears in the following example. This
table only contains fields that apply to basic call processing. Field FRTYPE
contains new values. Refer to the data schema section of the Translations
Guide for a description of the other fields.
Datafilling table RMMINV
Subfield or
Field
refinement
RMMNAME
SITENM
PMTYPE
RMMNO
DMS-100 Family XPM International Translations Reference Manual XPM12 and up
Datafilling BAS on RSC-S International
Basic call processing
Entry
Explanation and action
see list
RMM name. Enter the name for the RMM.
Contains subfields SITENM, PMTYPE, and
RMMNO.
alphanumeric
Site. Enter the site name assigned to the
remote location. This entry must also appear in
tables RCCINV, LCMINV, and SITE.
RMM
PM type.
0 to 63
RMM number. This number is different by office
and not by site.
—continued—
Explanation and action
This message indicates that the
RCO2 can connect to an LCM or
LCME (phase one) on P-side links.